Call Us Toll Free: 1-800-458-6153
Return To Main Interscan Home Page  |  Products  |  Tech Center  |  E-mail Us
Search Catalog
      GO   
 All Categories    Three Point Monitoring Systems - PLC Series - Hydrogen Peroxide
All Categories > Gas Detection Instruments And Systems > Multipoint (3 or more points) Continuous Monitoring Systems > Three Point Monitoring Systems - PLC Series - Hydrogen Peroxide > Item # SRPLC309-1000m  

Item # SRPLC309-1000m, Three Point Monitoring Systems - PLC Series - Hydrogen Peroxide


    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

PLC Multipoint Monitoring Systems include:
  • Displays real time gas concentrations in ppm
  • Dedicated sensor, sample pump, and digital flow switch for each monitoring location
  • All control and display functions at easy-to-use operator interface
  • User adjustable, LO & HI alarm set points, activating dedicated relays for each monitoring location
  • Stackable tower lights for LO, HI, and fault alarms, and Piezo horn for HI alarm common to all channels
  • Alarm event and time tracking, last time calibrated tracking, specific for each sensor
  • Pump vacuum fault detection and fault display
  • System packaged in wall-mountable NEMA 12 enclosure
  • 4-20 mA output - dedicated for each point






Specifications

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-1000 ppm

Resolution

1 ppm

Gas

Hydrogen Peroxide (H2O2)

Number of Detection Points

3

Application

Continuous

Includes Auto Zero

No

Note

The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor.


 DOWNLOADS 

Gas Detection Applications Primer

Sensor Principle of Operation

Interfering Gas Data

Gas Detection Knowledge Base

Multipoint (3 or more points) System Instruction Manual
(PDF, 0KB)

Hydrogen Peroxide Monitoring Applications

How Do I Get Started?

Interscan Video Library

H2O2-Toxic and Hazardous Properties




© Interscan Corporation
4590 Ish Drive #110 • Simi Valley, CA 93063–7682
TOLL FREE: (800) 458-6153 (US & Canada) • PHONE: (818) 882-2331
FAX: (818) 341-0642 • E-MAIL: info@gasdetection.com